Fire detection planned for your building.

Surveyed smoke and heat detection, manual call points and audible or visual warnings for workplaces. Monitoring and building interfaces are scoped separately.

Confirm detection, warning and building interfaces.

Detection

Select device types and positions for the rooms, activities and environmental conditions.

Warning

Assess how occupants will receive an alarm and specify the required warning devices.

Interfaces

Scope door release or ventilation control separately, including compatibility and testing.

Handover

Agree test records, user instructions and ongoing inspection responsibilities. Installation alone does not establish regulatory approval.

Fire detection designed for your building.

The design confirms detector positions, warning coverage, backup power and any building interfaces before installation.

Starting scope is shown below. A free survey and written quotation confirm final equipment, installation and ongoing services.

EN 54-certified wireless system

Essential Commercial Fire Package

Best for: single-floor offices, shops, restaurants, clinics, and small warehouses that need surveyed fire detection and warning. Interfaces are separately assessed.

The fire-safety survey determines detector coverage, warning devices, backup power and any interfaces. The listed equipment is an example starting configuration; additional devices may be required before installation.

Book a Fire Safety Survey

Equipment and scope

  • 1 fire hub 10-inch touchscreen, Ethernet, Wi-Fi, and two 4G SIM slots.
  • 1 backup battery Backup duration depends on battery capacity, load and condition.
  • 3 smoke and heat detectors Dual-spectrum smoke sensing and two heat sensors in each detector.
  • 1 siren with strobe Audible and visual warning in one device.
  • 1 manual call point Lets anyone raise the alarm by hand.
  • 1 automation module Compatible door-release and HVAC interfaces are assessed and configured for the agreed design.
  • Full installation Mounting, programming, testing, commissioning, staff training, and handover documents.

What a larger building may add

Multi-floor offices, schools, hotels, and large warehouses need more than three detectors. The survey maps each floor and lists exactly what your building needs before you approve anything.

Equipment and scope

  • Range extenders Carry the wireless signal across more floors or longer buildings.
  • More detection Additional detection selected for the rooms and risks identified in the survey.
  • More alarm points Extra manual call points, sirens, and strobes.
  • More automation Compatible building interfaces, subject to a surveyed design and commissioning tests.
  • Life-safety extras Exit signage, emergency lighting, extinguishers, and fire marshal training.

From survey to handover.

  1. Survey the building

    Review room use, layout, existing systems and alarm requirements.

  2. Approve the design

    Confirm devices, installation, interfaces and any monitoring charges.

  3. Commission and train

    Test the agreed cause-and-effect operation and hand over records and user instructions.

Taking over an existing fire alarm?

Review the installed system, records and building use before proposing changes.

  • Panel, detectors, warning devices and backup power.
  • Test records, configured interfaces and maintenance scope.

Before you book.

How much detection does my building need?

The survey determines detector type, quantity, positions, warning devices, backup power and any building interfaces. Three detectors are an example configuration, not a coverage allowance for every building.

Does installation guarantee an audit pass?

No. Fire safety also depends on escape routes, procedures, training, maintenance and other measures. The alarm installation has a defined scope and does not certify the entire building.

Can it release doors or stop ventilation?

Compatible interfaces can be designed for agreed functions. Door hardware, building systems and the cause-and-effect requirements must be assessed and tested together.

What happens if power or internet fails?

Local operation depends on the specified backup power and system design. Remote alerts need an available communication path. The survey and commissioning tests confirm the agreed arrangements.